  • [Radiation Measurements] A study on dose conversion from a material to human body using mesh phantom for retrospective dosimetry사후선량평가를 위한 Mesh 팬텀 이용 물질-인체 선량환산에 대한 연구

    KAERI / 김민채, 이정일*

  • 출처
    Radiation Measurements
  • 등재일
    July 2019
  • 저널이슈번호
    Volume 126, 106126
  • 내용

    바로가기  >

    Abstract
    In case of a radiation emergency, thermoluminescence (TL) and optically stimulated luminescence (OSL) measurements from materials in a mobile phone have been developed to enable classification of exposed individuals within a short period of time. A reconstructed dose from a mobile phone does not, however, correspond directly to a human body dose. Therefore, several studies were tried to convert a phone dose to a human body dose. Because of the difficulty in obtaining conversion factors experimentally, Monte Carlo simulations have been carried out using human phantoms for various accident situations. In recent years phantoms made of mesh have been developed to solve some problems in traditional voxel phantoms such as limited posture. In the present study, simulations using the GEANT4 computer code were performed to obtain conversion factors using mesh phantoms. The geometry of a mobile phone was designed, reflecting latest structures, and a display glass was selected as a dosimetric material due to its wide detection area with a high radiation sensitivity. Four different positions (chest, hip, thigh, and hand) of a mobile phone on the phantom were considered. In addition, six exposure conditions of anterior-posterior (AP), posterior-anterior (PA), left-lateral (LLAT), right-lateral (RLAT), isotropic (ISO), and rotational (ROT) exposure geometries and three different postures of standing, kneeling, and squatting were selected to reflect actual working situations. Three commonly used radiation sources (Iridium-192, Cesium-137, and Cobalt-60) were applied.

     

    Author information

    Min Chae Kim ab, Hyoungtaek Kim a, Haegin Han b, Jungil Lee a, Seung Kyu Lee a, Insu Chang a, Jang-Lyul Kim a, Chan Hyeong Kim b

    a
    Radiation Safety Management Division, Korea Atomic Energy Research Institute, 989-111 Daedeok-daero, Yuseong-gu, Daejeon, 34057, Republic of Korea
    b
    Department of Nuclear Engineering, Hanyang University, 222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Republic of Korea

  • 키워드
    Thermoluminescence (TL)Optically stimulated luminescence (OSL)Display glass of a mobile phoneMesh phantomRetrospective dosimtery