방사선방호 및 안전

본문글자크기
  • [Health Phys.] Internal Dose Assessment after 131I-Iodide Misadministration in a Patient With Incompletely Blocked Thyroid Uptake: Personalized Internal Dose Assessment by Estimating Individual-Specific Biokinetics.

    [Health Phys.] Internal Dose Assessment after 131I-Iodide Misadministration in a Patient With Incompletely Blocked Thyroid Uptake: Personalized Internal Dose Assessment by Estimating Individual-Specific Biokinetics. I-131 오투약 후 불완전 차단된 갑상선흡수에 따른 내부피폭선량 평가: 개인맞춤형 생물동역학 평가를 통한 개인 내부피폭선량평가

    KIRAMS / 권태은, 하위호*

  • 출처
    Health Phys.
  • 등재일
    2019 Jun
  • 저널이슈번호
    116(6):760-770. doi: 10.1097/HP.0000000000001019.
  • 내용

    바로가기  >

     

    Abstract
    In July 2017, a medical accident occurred in South Korea, in which I-iodide solution was misadministered to the wrong patient. Although the International Commission on Radiological Protection provided internal dose coefficients for iodine for blocked thyroid, they were not reliable enough for determining the dose to the patient (whose thyroid uptake was incompletely blocked) due to a discrepancy in biokinetics. Therefore, a personalized dose assessment was performed to derive the individual-specific dose coefficients for the patient. Initially, the thyroid biokinetics of the patient were statistically clarified by fitting bioassay monitoring results and the corresponding predicted bioassay values, which were calculated repeatedly for varying iodine transfer rates in an iodine biokinetic model. After determining the transfer rate for the patient, the individual-specific dose coefficients were then calculated in accordance with latest recommendations of the International Commission on Radiological Protection. According to the individual-specific biokinetics, the 24 h thyroid uptake fraction of iodine was estimated as 0.52%. The thyroid absorbed dose of the patient was evaluated as 21.2 Gy, which differed greatly (by about 9 Gy) from the dose evaluated simply using the reference data for blocked thyroid uptake. The personalized dose assessment carried out for the patient not only reduced considerable uncertainties in the internal dose calculation, but also improved the reliability of the calculated internal dose by adopting the latest dosimetric data, including specific absorbed fraction values based on voxel phantoms. Through the dose assessment of the patient, the methodology of personalized dose assessment considering individual-specific biokinetics was developed.

     


    Author information

    Kwon TE1, Park M1, Kang JK1, Cho M1, Jang S1, Kim KM2, Ha WH1, Jin YW1.
    1
    National Radiation Emergency Center, Korea Institute of Radiological and Medical Sciences, Seoul, Republic of Korea.
    2
    Research Institute of Radiological and Medical Science, Korea Institute of Radiological and Medical Sciences, Seoul, Republic of Korea.

     

    이달의 방사선의학 연구자 인터뷰 바로가기

  • 키워드
    biokinetics; dose assessment; internal dose; thyroid
  • 연구소개
    방사성의약품(131I 솔루션)이 오투약된 환자에 대한 내부피폭 선량평가를 위해 환자 고유의 Biokinetics를 도출 및 적용하는 개인맞춤형 선량평가 기술을 개발하여 보다 더 정확한 환자의 선량을 산출함.