의학물리학

본문글자크기
  • [Phys Med Biol .] Prostate segmentation accuracy using synthetic MRI for high-dose-rate prostate brachytherapy treatment planning

    Loyola University Chicago / 강혜주*

  • 출처
    Phys Med Biol .
  • 등재일
    2023 Jul 28
  • 저널이슈번호
    68(15). doi: 10.1088/1361-6560/ace674.
  • 내용

    바로가기  >

    Abstract
    Objective. Both computed tomography (CT) and magnetic resonance imaging (MRI) images are acquired for high-dose-rate (HDR) prostate brachytherapy patients at our institution. CT is used to identify catheters and MRI is used to segment the prostate. To address scenarios of limited MRI access, we developed a novel generative adversarial network (GAN) to generate synthetic MRI (sMRI) from CT with sufficient soft-tissue contrast to provide accurate prostate segmentation without MRI (rMRI).Approach. Our hybrid GAN, PxCGAN, was trained utilizing 58 paired CT-MRI datasets from our HDR prostate patients. Using 20 independent CT-MRI datasets, the image quality of sMRI was tested using mean absolute error (MAE), mean squared error (MSE), peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM). These metrics were compared with the metrics of sMRI generated using Pix2Pix and CycleGAN. The accuracy of prostate segmentation on sMRI was evaluated using the Dice similarity coefficient (DSC), Hausdorff distance (HD) and mean surface distance (MSD) on the prostate delineated by three radiation oncologists (ROs) on sMRI versus rMRI. To estimate inter-observer variability (IOV), these metrics between prostate contours delineated by each RO on rMRI and the prostate delineated by treating RO on rMRI (gold standard) were calculated.Main results. Qualitatively, sMRI images show enhanced soft-tissue contrast at the prostate boundary compared with CT scans. For MAE and MSE, PxCGAN and CycleGAN have similar results, while the MAE of PxCGAN is smaller than that of Pix2Pix. PSNR and SSIM of PxCGAN are significantly higher than Pix2Pix and CycleGAN (p < 0.01). The DSC for sMRI versus rMRI is within the range of the IOV, while the HD for sMRI versus rMRI is smaller than the HD for the IOV for all ROs (p ≤ 0.03).Significance. PxCGAN generates sMRI images from treatment-planning CT scans that depict enhanced soft-tissue contrast at the prostate boundary. The accuracy of prostate segmentation on sMRI compared to rMRI is within the segmentation variation on rMRI between different ROs.

     

     

    Affiliations

    Hyejoo Kang 1, Alexander R Podgorsak 1, Bhanu Prasad Venkatesulu 1, Anjali L Saripalli 1, Brian Chou 1, Abhishek A Solanki 1, Matthew Harkenrider 1, Steven Shea 2, John C Roeske 1, Mohammed Abuhamad 3
    1Department of Radiation Oncology, Stritch School of Medicine, Cardinal Bernadin Cancer Center, Loyola University Chicago, 2160 S. 1st Ave, Maywood, IL, United States of America.
    2Department of Radiology, Stritch School of Medicine, Cardinal Bernadin Cancer Center, Loyola University Chicago, 2160 S. 1st Ave, Maywood, IL, United States of America.
    3Department of Computer Science, Loyola University Chicago, 1032 W. Sheridan Rd, Chicago, IL, United States of America.

  • 키워드
    GAN; HDR prostate brachytherapy; Synthetic MRI; prostate segmentation.
  • 덧글달기
    덧글달기
       IP : 18.117.142.128

    등록